Gefran 2400: Strain Gauge/ Temperature Indicator w. alarm
Stock Code:
SKU: product options
The high resolution fast Gefran 2400 indicator, 96x48 (1/8 DIN) format, for measurement and alarming of pressure (direct and differential), displacement, force, temperature, process variables measured by amplified sensors.
CALCULATION CAPACITY
- Compare input variables, calculate the engineering unit, calculate flow rates, ratio, etc.
- Results can be used as process value / alarm setpoint / retransmitted output
TWO CHANNELS FOR MEASUREMENT / WEIGHING
- Two main inputs let you simultaneously make two rapid acquisitions with a single instrument.
- The instrument can supply up to 6 load cells in parallel
- Resolution: 100.000 points
EASY CALIBRATION
- Just enter the sensor label data
- You can always calibrate conventionally by using the menu.
The sampling valvue (80% standard) can be set for a strain- gauge
Sensor Inputs: | |
Number of inputs: | 2 Main, 2 Auxiliaries |
Types: | |
Thermocouples: | J, K, R, S, Tcon scale in ºC or ºF |
Resistance Thermometers: | RTd 2/3/4- wire, PT 100, scale ºC or ºF |
Thermistors: | -- |
Linear: | Strain gauge: 5/10Vdc 200mA, 350?? Potentiometer:?100?, Ri > 10M? @ 2.5 vdc DcLinear: 0/4...20mA (Ri = 50?) ?+ 100mV, Ri > 10M?; ±10V, Ri> 2M?; Auxiliary input: 0...10V (Ri ? 2M?); 0/4...20mA (Ri = 50?) Possible linearization on 64 segments |
Sampling time: | 2 msec |
Precision: | 0.1%f.s. ± 1 digit (0.2%f.s. for TC) |
Digital input: | 2, NPN or PNP, optoisolated, configurable function |
Outputs: | |
Maximum number of outputs: | max 4; can be expanded up to 10 relay or logic outputs with MD81 |
Types: | |
Relay: | 5 A, 250V contacts, resistive load |
Logic: | 24V (20mA, max 12V) |
Analog: | isolated 1500V, 0/4...20mA, Rmax = 500?, ± 10V, resolution 0,0%, configurable via software |
Transmitter power supply: | Isolated 1500V, 5, 10Vdc/200mA o 24 Vdc, ± 5% 100mA |
Power supply: | 11...27 Vac/dc ± 10%; 100...240 Vac/dc;± 10% 50/60 Hz, 12VA max., internal fuse |
Digital communication: | RS485 / RS232 (max 115200baud), protocoll MOD BUS RTU / PROFIBUS DP |
Faceplate protection level: | IP 65 |
Working temperature: | 0 to 50ºC |
![]() | |
Click here for more technical data |
Below is a list of tags that have been applied to this product. Clicking on a tag will display a list of all products with that tag applied.